EDI

API DocsTerminal
NEW!
Programmatically translate EDI to JSON with the EDI Core REST API
Get started in minutes →
Segment
in
X12 Release 008010

PSD Physical Sample Description

To define the physical sample parameters associated with a test resulting in discrete measurements
Sequence
Element
Name
Type
Requirement
Min
Max
Repeat
01
939
Sample Process Status Code
Identifier (ID)
Optional
2
2
1
Code specifying the stage in the product development cycle at which the specimen was selected for testing
Codes (2)
02
Sample Selection Method Code
Identifier (ID)
Optional
2
2
1
Code specifying the method of selecting the specimen
Codes (5)
03
Sample Frequency Value per Unit of Measurement Code
Numeric (N0)
Conditional
1
9
1
The number of samples collected
P0304
E0309
04
Composite Unit of Measure
Composite (composite)
Conditional
1
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
05
Sample Description Code
Identifier (ID)
Optional
2
2
1
Code specifying the physical configuration or condition of the test specimen
Codes (26)
06
Sample Direction Code
Identifier (ID)
Optional
2
2
1
Code specifying the direction in which the sample was collected or tested
Codes (16)
07
Position Code
Identifier (ID)
Optional
2
2
1
Code specifying the position of an item such as the location, within a specimen, from which the sample was taken; the position of a coupon within an advertisement; etc
Codes (29)
08
Description
String (AN)
Optional
1
80
1
A free-form description to clarify the related data elements and their content
PSD08 can provide a more complete description of the physical sampling location.
09
Sample Selection Modulus
Decimal number (R)
Conditional
1
6
1
To specify the sampling frequency in terms of a modulus of the Unit of Measure, e.g., every fifth bag, every 1.5 minutes
Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference and Mapping Guides are provided for marketing purposes and are free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.
Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference and Mapping Guides are provided for marketing purposes and are free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.